Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | VEIKONG |
Model Number : | VFD200A |
Certification : | CE ROHS |
Price : | negotiable |
Payment Terms : | L/C, T/T, Western Union, MoneyGram |
Supply Ability : | 15000pcs per Month |
Delivery Time : | 3 days, depend on the order |
7.5kw 10hp inverter 220V input 380v output variable frequency drive
Item | Specifications | ||
Standard functions | Maximum frequency | Vector control:0~500Hz V/F control: 0~500Hz | |
Carrier frequency | 0.5kHz~16kHz (The carrier frequency is automatically adjusted based on the load features.) | ||
Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% | ||
Control mode | Sensor-less flux vector control (SFVC) Closed-loop vector control (CLVC) (+PG Card) Voltage/Frequency (V/F) control | ||
Startup torque | 0.5Hz/150%(SVC);0Hz/180%(FVC) | ||
Speed range | 1:100 (SVC) | 1:1000 (FVC) | |
Speed stability accuracy | ±0.5%(SVC) | ±0.02%(FVC) | |
Torque control accuracy | ±5%(FVC) | ||
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current P type: 60s for 120% of the rated current, 3s for 150% of the rated current | ||
Torque boost | Auto boost; Manual boost: 0.1%~30.0% |
Standard functions | V/F curve | Straight-line V/F curve Multi-point V/F curve N-powerV/F curve (1.2-power, 1.4-power, 1.6-power, 1.8- power, square) |
V/F separation | 2 types: complete separation; half separation | |
Acceleration/deceleration curve | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00s~65000s | |
DC braking | DC braking frequency: 0.00 Hz ~ maximum frequency Braking time: 0.0~100.0s Braking trigger current value: 0.0%~100.0% | |
JOG control | JOG frequency range: 0.00Hz~50.00 Hz JOG acceleration/deceleration time: 0.00s~65000s | |
Built-in PLC, multiple speeds | It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states | |
Built-in PID | It realizes closed loop control system easily. | |
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage fluctuation. | |
Overvoltage/ Over current stall control | The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage/over current. | |
Rapid current limit function | It can auto limit running current of frequency inverter to avoid frequently tripping. | |
Torque limit and control | (Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process. Torque control can be implemented in the VC mode. |
Item | specification | |
Individualized functions | High performance | Control of asynchronous motor is implemented through the |
Instant power off not stop | The load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time. | |
Rapid current limit | To avoid frequently over current faults of the frequency inverter. | |
Virtual IO | Five sets of virtual input and output for simple logic control | |
Timing control | Time range: 0.0~6500.0 minutes | |
Multi-motor switching | Four sets of motor parameters for four motor switching control | |
Multiple communication protocols | Currently supports communication bus via Modbus-RTU and later will support PROFIBUS-DP, CANopen, etc. | |
Motor overheat protection | The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to | |
Multiple encoder types | It supports incremental encoder and encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/ COS encoder. | |
Running command | key panel | |
Frequency giving | There are 10 kinds frequencygiving: digital setting, analog voltage setting, analog current setting, pulse setting, serial communication port setting, panel potentiometer, etc. You can switch between these giving in various ways. |
VFD200A picture:
Connect wire diagram:
![]() |