110kw 150HP Pump Controller Solar Pumping Inverter with MPPT function
VEIKONG VFD500-PV series Solar Pumping Inverters
Power range: 0.75kw-75kw 220VAC
0.75kw-630kw 380VAC
1. Advanced MPPT Technology: Maximum MPPT Efficiency: 99%;
2. Auto-track All Daytime;
3. Auto dormancy/wake-up, Under-voltage restart;
4. Support both AC and DC power input (optional);
5. Water Level Monitoring: dry run protection, overflow protection
Record: generated power, pumped water, running time;
6. The whole water pumping systems running not rely on grid power
or battery;
7. Protection Functions: support low frequency, dormancy, dry-run,
over-current, minimum power and other protection functions;
8. Default Auto-running: auto-running by keypad, auto-running by
IoT, auto-running by Terminals;
9. Excellent Control Performance: make sure the system auto-running
with unattended, maximum output frequency is 600hz under VF
control;
10. Intelligent IoT: support GPRS module, for remote control.
| 220V | 380V | |
| Max input DC voltage | 450V | 810V | 
| DC voltage range | 150~450VDC | 300~810VDC | 
| Normal working DC voltage | 260V-400V | 400V-650V | 
| Recommended input mppt voltage | 330V | 550V | 
| MPPT efficiency | >99% | |
| Rated output voltage | 1/3-phase 220VAC | 3-phase 380-480VAC | 
Accessories:
1. GPRS (support 2g/3g/4g internet)
2. LCD keypad
3. Output Reactor
VFD500-PV solar pump inverter picture:
Mode Range
Drive model  | Max DC input current (A)  | Rated output current (A)  | Applicable water pump (kW)  | 
VFD500M-40T00150-PV  | 6.1  | 3.7  | 1.5  | 
VFD500M-40T00220-PV  | 7.1  | 5  | 2.2  | 
VFD500M-40T00400-PV  | 16.5  | 9.4  | 4  | 
VFD500M-40T00550-PV  | 23.9  | 13  | 5.5  | 
VFD500M-40T00750-PV  | 30.6  | 17  | 7.5  | 
VFD500-40T00150-PV  | 6.1  | 3.7  | 1.5  | 
VFD500-40T00220-PV  | 7.1  | 5  | 2.2  | 
VFD500-40T00400-PV  | 16.5  | 9.4  | 4  | 
VFD500-40T00550-PV  | 23.9  | 13  | 5.5  | 
VFD500-40T00750-PV  | 30.6  | 17  | 7.5  | 
VFD50040T01100-PV  | 39.2  | 25  | 11  | 
VFD500-40T01500-PV  | 49.0  | 32  | 15  | 
VFD500-40T01850-PV  | 57  | 37  | 18.5  | 
VFD500-40T02200-PV  | 69  | 45  | 22  | 
VFD500-40T03000-PV  | 91  | 60  | 30  | 
VFD500-40T03700-PV  | 114  | 75  | 37  | 
VFD500-40T04500-PV  | 146  | 90  | 45  | 
VFD500-40T05500-PV  | 190  | 112  | 55  | 
VFD500-40T07500-PV  | 237  | 152  | 75  | 
VFD500-40T09000-PV  | 273  | 176  | 90  | 
VFD500-40T11000-PV  | 319  | 210  | 110  | 
VFD500-40T13200-PV  | 389  | 253  | 132  | 
220V single phase or three phase level  | |||
VFD500-20T00075-PV  | 6.7  | 4.5  | 0.75  | 
VFD500-20T00150-PV  | 9.9  | 7  | 1.5  | 
VFD500-20T00220-PV  | 14.1  | 10.6  | 2.2  | 
VFD500-20T00400-PV  | 22.6  | 17  | 4  | 
VFD500M-20T00150-PV  | 9.9  | 7  | 1.5  | 
VFD500M-20T00220-PV  | 14.1  | 10.6  | 2.2  | 
Connect wire diagram

For 220V single phase motor connection
1: Single phase asynchronous motor wiring method (without starting capacitor):
Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;
Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.
First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ

For 220V single phase motor connection
2: Single-phase asynchronous motor wiring method (with capacitor)
Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ

| 
                                 |