Sign In | Join Free | My burrillandco.com
Home > MPPT VFD Solar Pump Inverter >

Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter from wholesalers
     
    Buy cheap Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter from wholesalers
    • Buy cheap Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter from wholesalers
    • Buy cheap Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter from wholesalers
    • Buy cheap Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter from wholesalers
    • Buy cheap Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter from wholesalers

    Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : depend on the order quantity
    • Product Details
    • Company Profile

    Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter

    2.2kw 3HP single phase 220V Solar water Pump Inverter for ac pump


    Performance features:(220v 0.75kw-75kw, 380v 0.75kw-160kw)

    Smart:
    Full automatic operation, no need programming, user-friendly
    Modular design, easy install , operate & maintain
    GPRS Moudle Support remote monitoring & control (2G/4G/WIFI for option)
    Support LogEfficie
    o/Lable/Color/Function OEM Serive


    Efficient:
    1:1 match to AC pumps with strong overload capacity
    30% more water output with advanced inverter control algorithm
    Maximum power point tracking (MPPT) efficiency reach 99% with advanced MPPT algorithm
    Built-in booster with lower solar operating voltage to reduce solar panels costs
    Good ROI (Return on Investment) against diesel powered pumping

    Reliable:
    Hybrid function –Solar power priority, grid power/generator dual input as compensation
    Key parts use famous brand components, longer service life
    Wide range of input voltage
    IP65 design, continuous full-load operation between -10℃ to +60℃
    Compatible with all AC pumps (0.37kw-150kw)
    Certification qualified from authoritative third party, inverters can be exported to all countries
    Professional & Independent R&D team, good service for pre-sales and after-sales
    Fast delivery and quick response

    Comprehensive Protections:
    Soft start
    DC Input Anti-reverse
    AC Input/Output Phase lost(3Phase)
    AC Output Short Circuit
    AC Output Unbalance (3Phase)
    Pump Dry run protection By sensor/ software
    Water Over Flow of Tank
    Solar Low power
    Over Load
    AC Output Over Current


    Electrical Specifications


    PV input
    Maxiumum input DC voltage400V DC
    Recommended MPPT voltage range250~350V DC
    Recommended input Operation Voltage310V DC
    Grid or backup generator input
    Input voltageSingle phase 220V(-15%~30%)
    Output Specification
    Rated output voltage3PH 220V
    Output frequency0~500.00Hz (default: 0~50.00Hz)
    380V Solar Pumping Inverter
    Input Specification
    PV input
    Maxiumum input DC voltage800V DC
    Recommended MPPT voltage range450~650V DC
    Recommended input Operation voltage540V DC
    Grid or backup generator input
    Input voltageThree phase 380V(-15%~30%)
    Output specification
    Rated ouput voltage3PH 380V
    Output frequency0~500.00Hz (default: 0~50.00Hz)
    Protection
    Built-in ProtectionLighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.

    General Parameters
    Application siteNo direct sunshine, no dust,corrosive gas,combustible gas, oil mist, steam,dripping or salinity etc.
    Altitude0~2000m
    Derated use above 1000m, per 100m, the rated output current decrease 1%
    Environment Temperature-10°C~40°C (Environment Temperature be 40°C~50°C, please keep derated use)
    Humidity5~95%, non-condensation
    Vibrationless than 5.9 m/s²(0.6G)
    Storage Temperature-20°C~+70°C
    EfficiencyRated Power Run≥93%
    InstallationWall or rail mounting
    Protectiion GradeIP20
    CoolingForced Air Cooling


    Accessories:


    1. GPRS (support 2g/3g/4g internet)


    2. Output reactor


    3. LCD keypad


    VEIKONG LCD display







    Model Range

    Drive ModelRelated VoltageMax DC input voltage (V)Rated output current (A)Applicable water pump (KW)SIZE
    VFD500M-20T00150-PV220V80071.5SIZE A
    VFD500M-20T00220-PV220V80010.62.2SIZE A
    VFD500M-40T00150-PV380V8004.21.5SIZE A
    VFD500M-40T00220-PV380V80062.2SIZE A
    VFD500-20T00150-PV220V80071.5SIZE A
    VFD500-20T00220-PV220V80010.62.2SIZE A
    VFD500-20T00400-PV220V800174SIZE A
    VFD500-40T00150-PV380V8004.21.5SIZE A
    VFD500-40T00220-PV380V80062.2SIZE A
    VFD500-40T00400-PV380V8009.44SIZE A
    VFD500-40T00550-PV380V800135.5SIZE B
    VFD500-40T00750-PV380V800177.5SIZE B
    VFD500-40T01100-PV380V8002511SIZE C
    VFD500-40T01500-PV380V8003215SIZE C
    VFD500-40T01850-PV380V8003818.5SIZE D
    VFD500-40T02200-PV380V8004622SIZE D
    VFD500-40T03000-PV380V8006030SIZE E
    VFD500-40T03700-PV380V8007537SIZE E
    VFD500-40T04500-PV380V8009645SIZE F
    VFD500-40T05500-PV380V80011255SIZE F
    VFD500-40T07500-PV380V80015075SIZE G
    VFD500-40T09000-PV380V80017690SIZE G
    VFD500-40T11000-PV380V800210110SIZE H
    VFD500-40T13200-PV380V800253132SIZE I
    VFD500-40T16000-PV380V800304160SIZE I
    VFD500-40T18500-PV380V800340185SIZE J
    VFD500-40T20000-PV380V800377200SIZE J


    FAQ
    1. How to achieve Automatic start after stop?
    If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
    As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
    and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
    2. How to design solar PV water pump system?
    Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
    the inverter. If needed, we will provide technical support online.
    3. How to use a float in the water tank to stop the pump if the tank is full?
    If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
    4. How to set minimum frequency ( for example) 30hz and maximum 50HZ
    Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07
    5. If pump is 60HZ frequency, how to set max frequency?
    Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
    Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
    phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32

    6. How to make the water pump system work without sunshine?

    Usually, solar PV water pump system can meet the needs of pumping water.
    If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design


    7. How to check and solve basic problem of inverter trips and error
    a:Check the total vmp and voc of solar panels ,solar panel technical data
    b:Check motor pump power and rated current
    c: Check the distance between motor and inverter
    d: Check trip record r25.00 r25.01 25.02 25.03 r26.00 r26.01 r26.02 r26.03
    e: Check troubleshooting fault and find relevant solutions
    f : Check if motor insulation has been damaged or motor is blocked


    Quality Professional R D Team and Good Service for Pre-Sales and After-Sales in MPPT VFD Solar Pump Inverter for sale