380v Three Phase AC EMI Filter electromagnetic interference filter
EMI Power Line Filter from the LC low-pass passive network
components.It uses principles of impedance mismatch,so that by
the attenuation of electromagnetic interference signals.
Filter filtering effect depends on the extent of impedance
mismatch,the greater the impedance difference, the better the
filter. For example,to get better results, for low-impedance power
supply side, should be accompanied by a high input
impedance of the filter;pairs of high input impedance of the load
side, then the filter with low output impedance.
Product Features
This catefory of products has superior capability of interference
containment and can be applied to data processing system,
telecommunication equipment inverter and power conditioning
equipment that impose high requirement on interference containment.
Rataed Voltage: AC 380V-440V
Test Voltage (1minute): Phase to Phase DC 1500V; Phase to Ground AC
1500V / DC 2500V
Operating Frequency: 50/60HZ
Range of temperature: -25-85℃
Insulation Resistance: Phase to ground (up to 300A) ≥ 1500MΩ
Model | Low Pass EMI Filter |
Transfer Function | Low Pass |
Package Type | Surface Mount |
Nominal Center Frequency | 10K-30MHZ |
Insertion Loss | 60~90dB |
Input Impedance | 50Ω |
Rated Voltage | 380V/440V |
Rated Current | 1A-100A |
Environmental Temperature | 40°C |
Temperature Range | 25 / 085 / 21 |
Operating Frequency | 50/60HZ |
Line to Line | 1450VDC |
Line to Ground | 2250VDC or 2000VAC |
Maximum Leakage Current | 115VAC/60HZ 1.4mA Max. 250VAC/60HZ 2.5mA Max |
MOQ | 5pcs |
Price | USD60~80/Meter |
Lead Time | 5~15 weekday for Low Pass EMI Filter |


Filter instructions
Consider the selection of the main filter insertion loss,the
manufacturer of the given curve (parameters) in general in the
standard 50-system test results are only for reference, but the
actual applications are generally not 50 systems, insertion loss
will
be some offset.
Filter selected second point to note are: operating voltage,
operating current, voltage value, leakage current, dimensions,
installation methods; special requirements and special applications
must be described when ordering.
DIN-type security choice of terminals: DIN security terminal has
the following features: touch security; internal solid, has great
access to cross-sectional area;in line with European industry
standards,than conventional terminals safer and more convenient;
use of DIN terminal of the filter is more in line with European
market requirements. Most of the products of SIKES to support the
kinds of terminal mode.


Insertion loss
Insertion loss (IL) is the ratio that filter access port voltage of
the circuit before and after, be expressed with the following:
Insertion loss (IL) = 20LgV1/V2
Where: V1- the interference signal voltage before filter access
V2- the interference signal voltage after filter access
Insertion loss test methods are detailed in the CISPR17
requirements. In general, product samples provided on the insertion
loss curve is obtained in the 50Ω system: the assumption on both
sides of the output power and load, input impedance is
resistive to 50Ω. As the actual use of the environment in the power
side and load side of the impedance vary greatly, so
when you get the actual use of the insertion loss values and the
samples of different nominal values of insertion loss.
Therefore, the selection of EMI power filter is the best way to
access equipment that it carried out the actual tests