Sign In | Join Free | My burrillandco.com
Home > VFD Variable Frequency Drive >

18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications from wholesalers
     
    Buy cheap 18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications from wholesalers
    • Buy cheap 18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications from wholesalers
    • Buy cheap 18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications from wholesalers
    • Buy cheap 18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications from wholesalers
    • Buy cheap 18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications from wholesalers

    18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-018G/022GT4B
    Certification : CE, ROHS
    Price : Please contact quotation
    Payment Terms : T/T, Western Union, L/C
    Supply Ability : 1000 units per week
    Delivery Time : depends on quantities
    • Product Details
    • Company Profile

    18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications


    18.5kw 25hp variable speed drive vsd for troque control heavy load application

    VFD500 advantages:
    1, With inside EMC C3 filter and building-block design for IO extension card and different kinds of PG card
    2, Top performance in our industry which represent in torque in less than 1hz 0.5hz 0.25hz 0.1hz and 0hz
    it can compare with any domestic chinese brand for output torque.
    3, Smooth running and stability, support optional LCD keypad and dual display keypad. support PC tools.
    4, Support modbus485, canopen, profinet communciation.
    5, Low noise on motor and fast response for 0.1S acceleration and deceleration without dead zone
    6, Reverse and forward free switching
    7, Sleeping function and energy saving function as well as in built PLC programming
    8, Tension control and torque mode control
    9, Support two group motor parameters which can realize two motor switching control




    VFD500 parameter distribution list:

    ClassificationParameter groupPage
    Common parameters00:Basic functionPage 37
    01:Frequency source selectionPage 39
    02:Start and stopPage 45
    03:Ramp and S curvePage 49
    04: Analog and pulse inputPage 51
    05:Analog and pulse outputPage 55
    06:Multi-function Digital input (DI)Page 56
    07: Multi-function Digital output(DO)Page 59
    08:Digital Output settingPage 62
    Motor control10:Encoder typePage 65
    11:Motor1 parmeterPage 66
    12:Motor1 VFcontrol parameterPage 68
    13:Motor1 Vector controlparameterPage 71
    14:Torque controlPage 73
    16:Energy saving controlPage 74
    Display and protection20:User-defined parametersPage 75
    21:Keypad and displayPage 77
    22:AC Drive configurationPage 79
    23:Drive protection function settingPage 81
    24:Motor protection parameterPage 85
    25:Fault tracking parameterPage 87
    26:Fault recording parameterPage 87
    27:Monitoring parameterPage 90
    Communication30:Modbus communicationPage 90
    31:Canopen communicationPage 92
    Application40:Process PID FunctionPage 92
    41:Sleep functionPage 98
    42:Simple PLCPage 100
    43:Programmable delay unitPage 102
    44:Comparator and logic unit/controllerPage 104
    45:Multifunction counterPage 108
    Motor 260:Motor2 basic parameterPage 110
    61:Motor2 parameterPage 111
    62:Motor2 VF control parameterPage 111
    63:Motor2 vector control parameterPage 111


    Energy saving control

    16 Group Energy saving control
    r16.00Electricity meter count (32BIT)Unit:KW/H-
    r16.02Output powerUnit:0.1kw,output power will be negative in regen state-
    r16.03Power factor-1.000~1.000-
    P16.04Electricity meter zero clearing0:no function;1111:clear to zero0
    P16.05Energy saving control0:disable
    1:enable
    0
    P16.06Energy saving voltage limit0%~50%(0% means Energy saving control disable and more than 0% means Energy saving control enable0%
    P16.07Energy saving filter time0.0~10.0s2.0s
    Notice:P16.05 is invisible(it is useful in vf control) and When energy saving enabled, the output current can be reduced and thepower loss can be reduced when the load is light.For example, the fan and pump is light loaded, most of the inverters do not have this function, so we are more energy efficient. Energy savings can be achieved when it is light loads or load changes so slow


    Quality 18.5kw 25hp VFD Variable Frequency Drive Top Performance for Heavy Load Applications for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)