Sign In | Join Free | My burrillandco.com
Home > VFD Variable Frequency Drive >

VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters from wholesalers
     
    Buy cheap VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters from wholesalers
    • Buy cheap VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters from wholesalers
    • Buy cheap VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters from wholesalers
    • Buy cheap VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters from wholesalers
    • Buy cheap VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters from wholesalers

    VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-022G/030GT4B
    Certification : CE, ROHS
    Price : Please contact quotation
    Payment Terms : T/T, Western Union, L/C
    Supply Ability : 1000 units per week
    Delivery Time : depends on quantities
    • Product Details
    • Company Profile

    VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters


    22kw 30hp variable frequency drive VFD AC DRIVE INVERTERS vector control

    Product Advantage


    1. Optimized external installation and internal structure and independent air flue design, fully enclosed electrical space design.


    2. Output automatic voltage regulation function (AVR), automatically adjust the output pulse width to eliminate the influence of the grid change on load.


    3. Built-in PID regulation function to facilitate the realization of closed loop control of the temperature, pressure and flow, and reduce the cost of the control system.


    4. Standard MODBUS communication protocol. Easy to achieve the communication between PLC, IPC and other industrial equipments.


    ItemSpecifiation
    InputInuput Voltage

    1phase/3phase 220V:200V~240V

    3 phase 380V-480V:380V~480V

    Allowed Voltage fluctuation range-15%~10%
    Input frequency50Hz / 60Hz,fluctuation less than 5%
    OutputOutput Voltage3phase:0~input voltage
    Overload capacity

    General purpose application:60S for 150% of the rated current

    Light load application:60S for 120% of the rated current

    ControlControl mode

    V/f control

    Sensorless flux vector control without PG card(SVC)

    Sensor speed flux vector control with PG card (VC)

    Operating modeSpeed control,Torque control(SVC and VC)
    Speed range

    1:100 (V/f)

    1:200( SVC)

    1:1000 (VC)

    Speed control accuracy

    ±0.5% (V/f)

    ±0.2% (SVC)

    ±0.02% (VC)

    Speed response

    5Hz(V/f)

    20Hz(SVC)

    50Hz(VC)

    frequency range

    0.00~600.00Hz(V/f)

    0.00~200.00Hz(SVC)

    0.00~400.00Hz(VC)

    Input frequency resolution

    Digital setting: 0.01 Hz

    Analog setting: maximum frequency x 0.1%

    Startup torque

    150%/0.5Hz(V/f)

    180%/0.25Hz(SVC)

    200%/0Hz(VC)

    Torque control accuracy

    SVC:within 5Hz10%,above 5Hz5%

    VC:3.0%

    V/f curve

    V / f curve type: straight line, multipoint, power function, V / f separation;

    Torque boost support: Automatic torque boost (factory setting), manual torque boost

    Frequency giving ramp

    Support linear and S curve acceleration and deceleration;

    4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

    DC bus voltage control

    Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


    Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


    VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

    VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

    Carrier frequency1kHz~12kHz(Varies depending on the type)
    Startup method

    Direct start (can be superimposed DC brake); speed tracking start

    Stop methodDeceleration stop (can be superimposed DC braking); free to stop
    Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN
    FunctionKeypadLED Digital keyboard and LCD keypad(option)
    Communication

    Standard:

    MODBUS communication

    CAN OPEN AND PROFINET( IN DEVELOPMENT)

    PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
    Input terminal

    Standard:

    5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

    2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

    Option card:

    4 digital input terminals

    2 analog input terminals.support-10V-+10V voltage input

    Output terminal

    standard:

    1 digital output terminal;

    1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

    1 relay output terminal(second relay is an option )

    2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

    Option card: 4 digital output terminals

    ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
    EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
    Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
    Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
    HumidityLess than 95%RH, without condensing
    VibrationLess than 5.9 m/s2 (0.6 g)
    Storage temperature-20°C ~ +60°C
    OthersInstallationWall-mounted, floor-controlled cabinet, transmural
    Protection levelIP20
    cooling methodForced air cooling
    EMCCE ROHS

    Internal EMC filter

    Complies with EN61800-3

    Category C3

    3rd Environment


    Replace famous brands vfd in general application.


    VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters


    VEIKONG VD500 application picture:


    VEIKONG 22kw 30hp VFD Variable Frequency Drive for Industrial with Vector Control and Inverters

    23 Group Drive protection function setting
    P23.00DC Bus voltage control option

    Ø Unit’digit :Overvoltage stall control
    0:overvoltage stall disabled
    1:overvoltage stall enabled
    2:overvoltage stall enabled self-adjustable

    Ø The over-voltage stall function limits the amount of power generated by the motor by extending the deceleration time or even increasing the speed, avoiding over-voltage on the DC side and reporting over-voltage faults
    Ten’unit:Undervoltage stall control
    0:undervoltage stall disabled
    1:Undervoltage stall(decelerate to zero speed and be in standby mode,after power restoring ,it will run again automatically)
    2: Undervoltage stall deceleration(decelerate to zero and stop)

    Ø The undervoltage stall function reduces the motor power consumption or reduces the power consumption of the motor or turns it into a power generation operation to avoid the undervoltage fault on the DC side.

    Ø The undervoltage stall function is used when the input power supply quality is poor (the power supply voltage fluctuates downward or the sporadic short power is suspended), and it is necessary to keep the inverter running as much as possible.

    01
    P23.01Overvoltage stall threshold220V Level: 320V~400V
    380V Level: 540V~800V
    480V Level:650V~950V
    Depend
    P23.02Undervoltage threshold220V level: 160V~300V
    380V level: 350V~520V
    480V level: 400V~650V
    Depend
    P23.03Overvoltage stall ratio0~10.01.0
    P23.04Undervoltage stall ratio0~20.04.0
    P23.05Undervoltage trip threshold220V Level:160V~300V
    380V Level:350V~520V
    480V Level:400V~650V
    Depend
    P23.06Undervoltage fault detecting time0.0s~30.0s1.0s
    P23.07Rapid current limit0:Disabled
    1:Enabled
    1
    P23.10Over-speed detection value0.0%~120.0% maximum frequency120.0%
    P23.11Over-speed detection time0.0s~30.0s0.:shielding1.0s
    P23.12Detection value of too large speed deviation0.0%~100.0%(motor rated frequency)20.0%
    P23.13Detection value of too large speed deviation

    0.0s~30.0s

    0.0:shielding

    0.0s
    P23.14Input phase loss detection time

    0.0s~30.0s

    0.0:forbidden

    8.0s
    P23.15Output phase loss inbalance detecting0%~100%30%
    P23.18Fault protection action selection 1Unit’s digit : input phase loss
    0: coast to stop
    1: Emergent stop
    2: Stop as per stop mode
    3: Continue to Run
    Ten’unit: user self-defined fault 1
    same as Unit’s digit
    Hundred’unit: user self-defined fault 2
    same as Unit’digit
    Thousand’s unit: communication fault
    same as unit’s digit
    0000
    P23.19Fault protection action selection 2Unit’s digit: motor overload
    0: Coast to stop
    1: Emergent stop
    2: Stop as per stop mode
    3: Continue to run
    Ten’unit: motor overheat
    same as unit’digit
    Hundred’unit: too large speed deviation
    same as unit’digit
    Thousand’s unit: motor over speed
    same as Unit’digit
    0000
    P23.20Fault protection action selection 3Unit’s digit: PID feedback lost during running
    0: Coast to stop
    1: Fast stop
    2: Stop as per stop mode
    3: Continue to run
    Ten’unit: Reserved
    same as unit’digit
    Hundred’unit: reserved
    same as unit’digit
    thousand’unit: reserved
    same as unit’digit
    0000
    P23.21Fault protection action selection 4Unit’s digit: output phase loss
    0: Coast to stop
    1: Fast stop
    2: Stop as per stop mode
    Ten’unit: EEPROM fault
    0: Coast to stop
    1: Fast stop
    2: Stop as per stop mode
    3: Continue to run
    Hundred’s unit: PG card fault(reserved)
    0: Coast to stop
    1: Fast stop
    2: Stop as per stop mode
    3: Continue to run
    Thousand’s unit: off load fault
    0: Coast to stop
    1: Fast stop
    2: Stop as per stop mode
    3: Continue to run
    0000
    P23.24Fault resetDefine as per bit:
    bit0-undervoltage;bit1- inverter overload
    bit2-inverter overheat ;bit3-motor overload
    bit4-motor overheat;bit5-user’fault 1
    bit6- user’fault 2; bit7~15 reserved
    0
    P23.25Fault source for auto resetDefine as per bit:
    bit0-overcurrent during acceleration;bit1-overcurrent during deceleration
    bit2-overcurrent during constant speed;bit3-over voltage during acceleration
    bit4-overvoltage during deceleratoin;bit5-overvoltage during
    bit6-inverter undervoltage;bit7-input phase loss
    bit8-inverter overload;bit9-inverter overheat
    bit10-motor overload;bit11-motor overheat
    bit12-user’fault 1;bit13-user’fault 2
    bit14-Reserved;bit15-Reserved
    0
    P23.26Fault auto Reset times0~990
    P23.27Numberic output Action at fault reset0:Disabled
    1:Enabled
    0
    P23.28Interval time of fault auto reset0.1s~300.0s0.5s
    P23.29Fault auto reset times clearing time0.1s~3600.0s10.0s
    P23.30Continuing Running frequency selection when trip0:Run at current frequency
    1:Run at setted frequency
    2:Run at upper limite frequency
    3:Run at lower limit frequency
    4:Run at abnormal back-up frequency
    0
    P23.31Abnormal back-up frequency

    0.0%~100.0%(maximum frequency )


    5.0%