Sign In | Join Free | My burrillandco.com
Home > Variable Frequency Inverters >

380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps from wholesalers
     
    Buy cheap 380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps from wholesalers
    • Buy cheap 380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps from wholesalers
    • Buy cheap 380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps from wholesalers
    • Buy cheap 380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps from wholesalers
    • Buy cheap 380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps from wholesalers

    380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500
    Certification : CE
    Price : Negotiable
    Payment Terms : Western Union, T/T, L/C, PayPal
    Supply Ability : 15000pcs per Month
    Delivery Time : 3 days, depend on the order quantity
    MOQ : Negotiable
    • Product Details
    • Company Profile

    380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps

    380V 22KW 30KW 37KW Variable Frequency Inverters For Submersible Pump


    1. Deceleration over excitation function


    Accurate thermal simulation platform software ensures the reliability of thermal simulation.


    Each VFD500 inverter has undergone thermal simulation testing, and only the physical prototype is developed within the scope of the thermal simulation safety design requirements. After the actual test, the thermal simulation results are very close to the physical test results. In the limit test state, the thermal simulation can replace the actual load simulation and an additional layer of scientific thermal test.


    2. Rigorous temperature rise test


    The whole machine temperature rise test uses the most severe cyclic overload test to meet the long-term reliable operation under extreme load conditions.


    Cyclic overload test: 1.5 times overload current for 1 minute, ambient current for 4 minutes, and 1.5 times operation for 1 minute at ambient temperature of 40°.


    This continuous cycle operation, 1 cycle for 5 minutes, until the system reaches the thermal equilibrium state, the whole machine is within the thermal design safety range.


    3. Complete protection


    The whole series has output to ground short circuit protection, over current protection, drive overload protection, motor overload protection, drive over temperature protection, optional PT100/PT1000 motor over temperature protection.


    According to the type of fault, it can be set as fault free stop, fault deceleration stop, fault continue to run, and facilitate the on-site handling of emergency situations.


    Adopting multiple high-quality three-proof paint to enhance the environmental adaptability of the product. The three-proof paint adopts the automatic spraying process to ensure the uniformity of the thickness of the coating and the consistency of the batch.


    Techinical Specifications


    Item

    Specifiation

    Input

    Input Voltage

    1phase/3phase 220V:200V~240V

    3 phase 380V-480V:380V~480V

    Allowed Voltage fluctuation range

    -15%~10%

    Input frequency

    50Hz / 60Hz,fluctuation less than 5%

    Output

    Output Voltage

    3phase:0~input voltage

    Overload capacity

    General purpose application:60S for 150% of the rated current

    Light load application:60S for 120% of the rated current

    Control

    Control mode

    V/f control

    Sensorless flux vector control without PG card(SVC)

    Sensor speed flux vector control with PG card (VC)

    Operating mode

    Speed control,Torque control(SVC and VC)

    Speed range

    1:100 (V/f)

    1:200( SVC)

    1:1000 (VC)

    Speed control accuracy

    ±0.5% (V/f)

    ±0.2% (SVC)

    ±0.02% (VC)

    Speed response

    5Hz(V/f)

    20Hz(SVC)

    50Hz(VC)

    frequency range

    0.00~600.00Hz(V/f)

    0.00~200.00Hz(SVC)

    0.00~400.00Hz(VC)

    Input frequency resolution

    Digital setting: 0.01 Hz

    Analog setting: maximum frequency x 0.1%

    Startup torque

    150%/0.5Hz(V/f)

    180%/0.25Hz(SVC)

    200%/0Hz(VC)

    Torque control accuracy

    SVC:within 5Hz10%,above 5Hz5%

    VC:3.0%

    V/f curve

    V / f curve type: straight line, multipoint, power function, V / f separation;

    Torque boost support: Automatic torque boost (factory setting), manual torque boost

    Frequency giving ramp

    Support linear and S curve acceleration and deceleration;

    4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

    DC bus voltage control

    Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


    Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


    VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

    VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

    Carrier frequency

    1kHz~12kHz(Varies depending on the type)

    Startup method

    Direct start (can be superimposed DC brake); speed tracking start

    Stop method

    Deceleration stop (can be superimposed DC braking); free to stop

    Maincontrol function

    Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN

    Function

    Keypad

    LED Digital keyboard and LCD keypad(option)

    Communication

    Standard:

    MODBUS communication

    CAN OPEN AND PROFINET( IN DEVELOPMENT)

    PG card

    Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card

    Input terminal

    Standard:

    5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

    2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

    Option card:

    4 digital input terminals

    2 analog input terminals.support-10V-+10V voltage input

    Output terminal

    standard:

    1 digital output terminal;

    1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

    1 relay output terminal(second relay is an option )

    2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

    Option card: 4 digital output terminals

    Protection

    Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function

    Environment

    Installation location

    Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

    Altitude

    0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m

    Ambient temperature

    -10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C

    Humidity

    Less than 95%RH, without condensing

    Vibration

    Less than 5.9 m/s2 (0.6 g)

    Storage temperature

    -20°C ~ +60°C

    Others

    Installation

    Wall-mounted, floor-controlled cabinet, transmural

    Protection level

    IP20

    cooling method

    Forced air cooling

    EMC

    CE ROHS

    Internal EMC filter

    Complies with EN61800-3

    Category C3

    3rd Environment


    Product Application


    380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps


    380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps


    FAQ:


    1. What voltage range can you support?

    Single-phase 220v input, single-phase 220v output;
    Single-phase 220v input, three-phase 220v output;
    Three-phase 220v input, three-phase 220v output;
    Single-phase 220v input, three-phase 380v output;

    380v input, 380v output, from 0.4KW-710KW.


    2. What is the standard of package?

    Below 37kw, it's carton package; 45kw and above, it's wooden package.


    3. Do you accept OEM business?

    We accept OEM and ODM with your autherization.

    Quality 380V 22KW 30KW 37KW Variable Frequency Inverters for Submersible Pumps for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)