Sign In | Join Free | My burrillandco.com
Home > MPPT VFD Solar Pump Inverter >

Support optional LCD keypad you will know all parameters meaning no need user manual

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Support optional LCD keypad you will know all parameters meaning no need user manual from wholesalers
     
    Buy cheap Support optional LCD keypad you will know all parameters meaning no need user manual from wholesalers
    • Buy cheap Support optional LCD keypad you will know all parameters meaning no need user manual from wholesalers
    • Buy cheap Support optional LCD keypad you will know all parameters meaning no need user manual from wholesalers
    • Buy cheap Support optional LCD keypad you will know all parameters meaning no need user manual from wholesalers
    • Buy cheap Support optional LCD keypad you will know all parameters meaning no need user manual from wholesalers

    Support optional LCD keypad you will know all parameters meaning no need user manual

    Ask Lasest Price
    Brand Name : VEIKONG
    Model Number : VFD500-PV
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 15000pcs per Month
    Delivery Time : depend on the order quantity
    • Product Details
    • Company Profile

    Support optional LCD keypad you will know all parameters meaning no need user manual

    2.2KW 4KW GPRS Pump Inverter Solar VFD For Solar Irrigation System


    2.2KW 4KW Solar Pump Inverter GPRS Solar VFD For Pump Solar Irrigation System


    VEIKONG IS Solar Ac Pump Controller chinese manufacturer

    Performance features:(220v 0.75kw-75kw, 380v 0.75kw-250kw)
    Features:
    1. Support Hybrid solar power and ac power at same time
    2. Support optional LCD keypad, you will know all parameters meaning , no need user manual
    3. Support optional GPRS module to remote control and monitor solar pumping situation
    4. Support optional output reactor to protect the motor
    5. Support water full, dry running, wake and sleep protection functions.


    Electrical Specifications


    PV input
    Maxiumum input DC voltage400V DC
    Recommended MPPT voltage range250~350V DC
    Recommended input Operation Voltage310V DC
    Grid or backup generator input
    Input voltageSingle phase 220V(-15%~30%)
    Output Specification
    Rated output voltage3PH 220V
    Output frequency0~500.00Hz (default: 0~50.00Hz)
    380V Solar Pumping Inverter
    Input Specification
    PV input
    Maxiumum input DC voltage800V DC
    Recommended MPPT voltage range450~650V DC
    Recommended input Operation voltage540V DC
    Grid or backup generator input
    Input voltageThree phase 380V(-15%~30%)
    Output specification
    Rated ouput voltage3PH 380V
    Output frequency0~500.00Hz (default: 0~50.00Hz)
    Protection
    Built-in ProtectionLighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.


    Accessories:


    1. GPRS (support 2g/3g/4g internet)


    2. Output reactor


    3. LCD keypad








    Model Range

    Drive ModelRelated VoltageMax DC input voltage (V)Rated output current (A)Applicable water pump (KW)SIZE
    VFD500M-20T00150-PV220V80071.5SIZE A
    VFD500M-20T00220-PV220V80010.62.2SIZE A
    VFD500M-40T00150-PV380V8004.21.5SIZE A
    VFD500M-40T00220-PV380V80062.2SIZE A
    VFD500-20T00150-PV220V80071.5SIZE A
    VFD500-20T00220-PV220V80010.62.2SIZE A
    VFD500-20T00400-PV220V800174SIZE A
    VFD500-40T00150-PV380V8004.21.5SIZE A
    VFD500-40T00220-PV380V80062.2SIZE A
    VFD500-40T00400-PV380V8009.44SIZE A
    VFD500-40T00550-PV380V800135.5SIZE B
    VFD500-40T00750-PV380V800177.5SIZE B
    VFD500-40T01100-PV380V8002511SIZE C
    VFD500-40T01500-PV380V8003215SIZE C
    VFD500-40T01850-PV380V8003818.5SIZE D
    VFD500-40T02200-PV380V8004622SIZE D
    VFD500-40T03000-PV380V8006030SIZE E
    VFD500-40T03700-PV380V8007537SIZE E
    VFD500-40T04500-PV380V8009645SIZE F
    VFD500-40T05500-PV380V80011255SIZE F
    VFD500-40T07500-PV380V80015075SIZE G
    VFD500-40T09000-PV380V80017690SIZE G
    VFD500-40T11000-PV380V800210110SIZE H
    VFD500-40T13200-PV380V800253132SIZE I
    VFD500-40T16000-PV380V800304160SIZE I
    VFD500-40T18500-PV380V800340185SIZE J
    VFD500-40T20000-PV380V800377200SIZE J

    Trial run(How to start solar pump inverter)
    Make sure all cables connections of solar panel and pump motor correct and no
    need to set any parameter, if you want to set parameter, you can do as follows.
    Step 1: (Keypad control):Set motor parameter P11.02- P11.06 as per motor pump name
    plate If dry run protection is required, measure the unload protection current(see details in
    user manual chapter for dry run function) If dry run protection not required then miss this step
    and go to step 2.
    Step 2: Set other related special solar pump parameters for optimization if needed.
    Step 3: After trial run finishing, if motor pump still not output water when inverter is running
    more than 40 Hz. Please disconnect the power supply and replace any two-phase wiring of
    the motor

    Technical Questions and solutions

    1. How to achieve Automatic start after stop?
    If it is controlled by keyboard, so there is no need to set any parameter(P47.03 waiting time)If you want to
    control by external switch. First set P00.06=1 and use a wire or switch to connect com and DI1,When the
    switch is closed, the drive run, when the switch is open, the drive stop
    2. How to use a float in the water tank to stop the pump if the tank is full?
    If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
    143.Use level probe in the well for protection against dry running
    1 st solution: See self learning of dry run(For LED display)
    2 nd solution: do it manually Set P24.13=30%-60%(as per real empty load current percentage based on
    rated current) and P24.14 P24.16 and P23.21
    3 rd solution: If your sensor is digital switch, just short D4 and com
    4 th solution: If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and
    P41.03-P41.06

    Quality Support optional LCD keypad you will know all parameters meaning no need user manual for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Veikong Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)